LOSS FACTOR METER MODEL: LPO-5D

MAIN FEATURES

  • specially designed to measure tand under actual working condition of L.T./H.P. Capacitors
  • The instrument provides in digital version makes use of the fact that current through the capacitor will not lead exactly by 90°C from the voltage across it.
  • A separate ‘NULL’ control along with the panel meter is provided to compensate for voltage fluctuations and any other variations in the circuitry components.
  • Measurement is done at A.C. voltage in the range of 200V to 600V at 50Hz.
  • Measures tand as low as 0.0002 and indication is directly given on the Digital Panel Meter (DPM).
  • The measurement of Loss Factor can be done for capacitors in the range of 1uF to 1000uF
  • The speed of measurement can be at the rate of 100 pcs. Per hour.
  • Fully solid state using latest state of art technology. The equipment is immune to short circuit, Wrong selection of ranges, Voltage fluctuations & other type of mis-handling which is likely to occur during the use by unskilled operations.

Technical Features

Capacitance Range

1uF to 1000uF

Loss Factor Range

19.99% F.S.D. with a resolution of 0.01% tan d.

Accuracy

10.01% ±1 digit (0.0001 tan d )

A.C. Voltage (applicable by external power supply at 50Hz)

200V to 600V

Indication

3 ½ digit panel meter

Speed with suitable Jig

100 Pcs. Per hour

Warm up time

3 minutes

Ambient Temperature

0°C to 50°C

Power

230VAC ±10%, 50Hz

Dimensions

430 X 230 X 210 mm

Weight

7 Kgs