MLS11DA & HLS12A

Technical Features
Test Voltage
0 – 12 kV
Rated Current
200mA
Automatic Balancing through windows based software
Automatic & software controlled voltage setting to avoid abrupt voltage rise.
Automatic selection of seven different modes of operation for measurement of 3 terminal object from windows based software.
1) UST-Ungrounded Specimen Test – 3 Combinations
This mode is used when the object under test is not grounded This test provides most accurate results
1) GST-Grounded Specimen Test
This mode is used when the object under test is permanently grounded This test is used more often in outdoor installations, power systems etc.
1) GST-Grounded Specimen Test with guard. 3 Combinations
This mode is used for measuring them stray capacitances and separating them from basic measurement in GST mode.
Standard Capacitance
100pF, 14kV built-in
Input Frequency
From 50 Hz (line frequency), +/-5%
Power Required
230V AC +/-10%, 1 phase AC, 50Hz
Safety Features
Zero start Control
Open Ground Indication Lamp with double grounded connection
External Interlock
HT cut-off on overload
HT ON & Supply ON Indication
All operating controls at earth potential
Necessory terminals & Sockets for connection to Bridge
Safety Specifications
Safety Specifications
Vibration Suitability
ASTM D 999 complied
Warm Up Time
1 minute
Power Supply
230VAC ±15%, 50Hz