Auto RC50H, Auto RC30H, Auto RC100H

Parameter Range Units Accuracy of Reading Comments
Conductor Resistance
0.0 to 100.0

0 to 1000

0 to 10 K
ohms

ohms

kohms
±0.1%rdg±0.05 range

±0.1%rdg±0.05%of range

±0.1%rdg±0.05%of range
4 Terminal (Wire) DC Measurement corrected to 20°C
Loop Resistance
Calculate from conductor resistance (Ra+Rb)
Mutual Capacitance
0.00 to 10.00

0.00 to 100.00

0.00 to 1000
nF

nF

nF
±0.5%rdg±0.05%of range

±0.5%rdg±0.05%of range

±0.5%rdg±0.05%of range
Bridge Method 1KHz/800 Hz.
Capacitance Unbalance Pair to Ground (CUPG) Pair to Pair (CUPP) (For CUPP : within quad & quad to quad).
0.000 to ± 1.999

0.000 to ± 19.99

0.000 to ± 1.999

0.000 to ± 19.99
nF

nF

nF

nF
±2%rdg±0.3% of range

±2%rdg±0.3% of range

±1.5%rdg±2pF

±1.5%rdg±0.3% of range
Bridge Method 1KHz /800Hz.
Attenuation At 150KHz
0.1 to 20

20 to 50

50 to 80
dB

dB

dB
±0.3dB

±0.8dB

±1.2dB
Balanced System Termination
Atn @ 800Hz

Atn @ 5KHz

Atn @ 21KHz
Derived from LF parameters.
CROSS TALK

(NEXT/FEXT)

@ 800KHz, @ 500KHz,
@ 21KHz, @150KHz
20 to 50

50 to 801

80 to 95
dB

dB

dB
±0.8dB

±1.2dB

±3dB
Standard Measurement Frequency 150KHz
CHARACTERISTIC IMPEDANCE @800Hz, 5KHz, 21KHz)
Derived from LF parameters.