ATRM1M

Technical Features
Power Supply
230V +/-10% , 50 Hz, single phase
Test Voltage
4.8V / 48V AC +/-5%
Ratio
Ratio Range
Display
Resolution
Accuracy
10
0.8 – 10
0.001
± 0.010
100
10 – 100
0.01
±0.10
1000
100 – 1K
0.1
± 1.0
10000
1K – 10K
1
±10
Phase Angle Deviation
Range
+/- 90 deg
Resolution
0.1deg
Accuracy
+/-1deg
Excitation Current
Range
2Amp
Resolution
0.1mA
Accuracy
+/-1% +/- 2digits
Trip Current
2A @ 8V range
Display
4 Line 20 character LCD display for
Ratio,440 X 340 X 170 mm
Excitation Current and
Phase Angle Deviation.
Accuracy
0.1% of the FSD +/-3 digits
Weight
Approximately 7 Kg
Dimension
440 X 340 X 170 mm