ADST-03

Resistance Test Test Method 4 wire Kelvin (Auto Ranging)
Resistance Range
CURRENT
2mΩ-20mΩ
2A
20mΩ-200mΩ
2A
200mΩ-2Ω
200mA
2Ω-20Ω
20mA
20Ω-200Ω
2mA
200Ω-2kΩ
0.2mA
2kΩ-20kΩ
0.2mA
Resistance Unbalance Test
Unit : %.
Formula Used : [(RA+RB)/RA-RB)] X 100.
Surge Comparison Test
Test Voltage
500V to 3000V (optional:5000V to 1000V)
Voltage Accuracy
±3%
Pulse Energy
0.5 Joules (Max.) – Can be customized.
Comparison
Highly reliable, error index, Algorithm with settable PASS/FAIL.
AC High Voltage Test
Test Voltage
100V to 3000 Volts
Current
0-20mA or 0-100mA (Max)
Resolution
0.1mA. (arc detection for improved fault detection)
Voltage Accuracy
±5
Trip Limit
Programmable up to 20mA or 100mA
Duration
1 to 60Sec
Insulation Resistance Test
Test Voltage
500V DC
Settable Pass/Fail
100MΩ to 1000MΩ
Inductance Test: (at 1Khz)
20µH to 200µH
Accuracy: ±2% of FSD
200µH to 2000µH
Accuracy: ±2% of FSD
2mH to 20mH
Accuracy: ±2% of FSD
20mH to 200mH
Accuracy: ±2% of FSD
200mH to 2000mH
Accuracy: ±2% of FSD
2H to 20H
Accuracy: ±2% of FSD