Tubestiles

Technical Features
Walkway Passage
598 x 1950 mm (+/-10 mm)
Door Locking
Electro-magnetic Locks are used to keep both the doors lock in the rest position
Main Supply
230V AC +/-10% 50Hz, Single Phase
Power Consumption
Standby: 120Watt max, During Operation:- 240 Watt Max
Drive
BLDC Motors based drive. Motor 24 Volts DC
Intelligence
32 bit Micro-controller Based
Sensors
# Absolute encoders to detect operation.
# Weighing Scale to detect presence of person inside the booth
# Duel Zone Safety Mat for multi-person detection
Emergency Release
In case of emergency both doors are opened
Throughput
4-5 peoples per minute.
Orientation
Walkway functions as both entry and exit.
Integration
With any access control device/panel/reader PFC of one second pulse required.
Fail Safe
Both doors can be opened manually incase of power failuer.